%0 Journal Article %T Coupled Eulerian-Lagrangian model prediction of neural tissue strain during microelectrode insertion. %A O'Sullivan KP %A Coats B %J J Neural Eng %V 21 %N 4 %D 2024 Aug 14 %M 39074496 %F 5.043 %R 10.1088/1741-2552/ad68a6 %X Objective.Implanted neural microelectrodes are an important tool for recording from and stimulating the cerebral cortex. The performance of chronically implanted devices, however, is often hindered by the development of a reactive tissue response. Previous computational models have investigated brain strain from micromotions of neural electrodes after they have been inserted, to investigate design parameters that might minimize triggers to the reactive tissue response. However, these models ignore tissue damage created during device insertion, an important contributing factor to the severity of inflammation. The objective of this study was to evaluate the effect of electrode geometry, insertion speed, and surface friction on brain tissue strain during insertion.Approach. Using a coupled Eulerian-Lagrangian approach, we developed a 3D finite element model (FEM) that simulates the dynamic insertion of a neural microelectrode in brain tissue. Geometry was varied to investigate tip bluntness, cross-sectional shape, and shank thickness. Insertion velocities were varied from 1 to 8 m s-1. Friction was varied from frictionless to 0.4. Tissue strain and potential microvasculature hemorrhage radius were evaluated for brain regions along the electrode shank and near its tip.Main results. Sharper tips resulted in higher mean max principal strains near the tip except for the bluntest tip on the square cross-section electrode, which exhibited high compressive strain values due to stress concentrations at the corners. The potential vascular damage radius around the electrode was primarily a function of the shank diameter, with smaller shank diameters resulting in smaller distributions of radial strain around the electrode. However, the square shank interaction with the tip taper length caused unique strain distributions that increased the damage radius in some cases. Faster insertion velocities created more strain near the tip but less strain along the shank. Increased friction between the brain and electrode created more strain near the electrode tip and along the shank, but frictionless interactions resulted in increased tearing of brain tissue near the tip.Significance. These results demonstrate the first dynamic FEM study of neural electrode insertion, identifying design factors that can reduce tissue strain and potentially mitigate initial reactive tissue responses due to traumatic microelectrode array insertion.