%0 Journal Article %T Values and Diagnostic Accuracy of Electrodiagnostic Findings in Carpal Tunnel Syndrome Based on Age, Gender, and Diabetes. %A Abuzinadah AR %J Diagnostics (Basel) %V 14 %N 13 %D 2024 Jun 28 %M 39001271 %F 3.992 %R 10.3390/diagnostics14131381 %X BACKGROUND: Appropriate cut-off values and diagnostic accuracy (DA) [sensitivity, specificity, predictive values, positive (PPV) and negative (NPV)] of electrodiagnostic findings for carpal tunnel syndrome (CTS) based on age, gender, and diabetes mellitus (DM) were not reported.
METHODS: In a retrospective study, we described the latency difference values and DA of comparative latency studies COLS [median to ulnar through palmar difference (palmdiff) and ring difference study (ringdiff), median to radial through thumb difference study (thumbdiff), and combined sensory index (CSI)] among non-CTS and CTS groups based on age, DM, and gender.
RESULTS: We included 632 patients (228 without CTS and 404 with CTS). For PPV > 90% and NPV > 50%, the best cut-offs among patients without DM, were 0.5ms, 0.8-1 ms, 1.4 ms, and 2 ms for palmdiff, thumbdiff, CSI (age < 60 years), and CSI (age > 60 years), respectively. The best cut-offs among patients with DM were 0.5 ms, 1.2 ms, 0.8 ms, 1.0-1.2 ms, 1.8 ms, 1-1.2 ms, 3.0 ms, and 3.5 ms for palmdiff (age < 50 years), palmdiff (age > 50 years), thumbdiff (age < 40 years), thumbdiff (age 40-59 years), thumbdiff (age > 60 years), CSI (age < 50 years), CSI (age 50-59 years), and CSI (age > 60 years), respectively.
CONCLUSIONS: The cut-off values of COLS to confirm CTS and their DA were different according to age and DM.