%0 Journal Article %T Comparison of Anti-Hepatitis A Antibody Pharmacokinetics in Healthy Australian Subjects Receiving Standard or Weight-Based Dosing of Polyvalent Immunoglobulin. %A Young MK %A Ng SK %A Faddy HM %A Nimmo GR %J J Clin Pharmacol %V 0 %N 0 %D 2024 Jul 5 %M 38967110 %F 2.86 %R 10.1002/jcph.2491 %X This randomized controlled trial compared two dosing regimens of the polyvalent immunoglobulin available for hepatitis A post-exposure prophylaxis in Australia. Participants were randomized to receive either 270 IU (standard dose) or 3.375 IU/kg (dose by weight). Quantitative serial serum hepatitis A antibody concentrations were measured at baseline and then on days 1, 3, 7, 28, and 50. Fifteen participants completed the trial. Serum hepatitis A antibody concentrations were not different between the study groups at any time point. Pharmacokinetic parameters estimated from participant data were not different between the study groups. The hepatitis A antibody level of all participants exceeded 10 mIU/mL at day 50. While no difference between dosing regimens was found in this study, further research should examine dosing at the lower limit of current Australian recommendations before making policy decisions.