%0 Journal Article %T In vitro experimental conditions and tools can influence the safety and biocompatibility results of antimicrobial electrospun biomaterials for wound healing. %A Põhako-Palu K %A Lorenz K %A Randmäe K %A Putrinš M %A Kingo K %A Tenson T %A Kogermann K %J PLoS One %V 19 %N 7 %D 2024 %M 38950036 %F 3.752 %R 10.1371/journal.pone.0305137 %X Electrospun (ES) fibrous nanomaterials have been widely investigated as novel biomaterials. These biomaterials have to be safe and biocompatible; hence, they need to be tested for cytotoxicity before being administered to patients. The aim of this study was to develop a suitable and biorelevant in vitro cytotoxicity assay for ES biomaterials (e.g. wound dressings). We compared different in vitro cytotoxicity assays, and our model wound dressing was made from polycaprolactone and polyethylene oxide and contained chloramphenicol as the active pharmaceutical ingredient. Baby Hamster Kidney cells (BHK-21), human primary fibroblasts and MTS assays together with real-time cell analysis were selected. The extract exposure and direct contact safety evaluation setups were tested together with microscopic techniques. We found that while extract exposure assays are suitable for the initial testing, the biocompatibility of the biomaterial is revealed in in vitro direct contact assays where cell interactions with the ES wound dressing are evaluated. We observed significant differences in the experimental outcome, caused by the experimental set up modification such as cell line choice, cell medium and controls used, conducting the phosphate buffer washing step or not. A more detailed technical protocol for the in vitro cytotoxicity assessment of ES wound dressings was developed.