%0 Journal Article %T Double implantation of Xen 45 gel stent in primary open-angle glaucoma: a pilot study. %A Grosso A %A Ceruti P %A Garlasco J %A Fröhlich J %A Orione M %A Gugleta K %A Fioretto M %A Calzetti G %J Int Ophthalmol %V 44 %N 1 %D 2024 Jun 21 %M 38904834 %F 2.029 %R 10.1007/s10792-024-03153-2 %X OBJECTIVE: To describe the outcomes of double implantation of Xen 45 Gel Stent (Xen) using an ab externo approach with closed conjunctiva.
METHODS: Retrospective single-centre case series of primary open-angle glaucoma patients with at least six months of follow-up after implantation of a second Xen in the same eye via ab externo technique without conjunctival opening.
RESULTS: Eight pseudophakic eyes of 8 patients were included. Intraocular pressure (IOP) dropped from 30 ± 2.6 mmHg pre-operatively to 22.4 ± 2.3 mmHg one month after the first Xen implant (mean difference: -7.6 mmHg [95% confidence interval: -9.4, -5.9 mmHg], p = 0.0092). A second Xen was then implanted to achieve the target IOP. The procedure showed no significant intraoperative or postoperative complications. The IOP dropped to 16.1 ± 2.7 mmHg six months following this second implant (mean difference: -6.3 mmHg [95% confidence interval: -7.2, -5.3 mmHg], p = 0.0183); however, 3 patients needed medical therapy to further reduce the IOP towards the target value.
CONCLUSIONS: Sequential implantation of two Xen 45 Gel Stents using an ab externo approach with closed conjunctiva appears a promising procedure that showed a favorable safety and efficacy profile in this small case series. This pilot data might pave the way for further studies to evaluate the safety and efficacy of the procedure.