%0 Case Reports %T Pseudo Elevation of TSH and ACTH Caused by Heterophilic Antibodies: a Case Report and Literature Review. %A Sun HG %A Xu XP %A He LQ %J Clin Lab %V 70 %N 6 %D 2024 Jun 1 %M 38868895 %F 1.053 %R 10.7754/Clin.Lab.2024.240122 %X BACKGROUND: TSH and ACTH are crucial hormones for diagnosing thyroid and adrenal diseases, and incorrect test reports can cause significant harm to patients.
METHODS: The TSH and ACTH levels on the testing system of our laboratory were measured using "sandwich" assays. The patient had heterophilic antibodies in their body, causing a false increase in TSH and ACTH levels.
RESULTS: TSH on the Abbott platform was 59.7 μIU/mL and on the Roche platform it was 4.33 μIU/mL. After pretreatment with HBR it was 3.95 μIU/mL; ACTH on the SIEMENS platform was 263.5 pg/mL, on the Abbott platform it was 47.6 pg/mL. After pretreatment with HBR it was 36.5 pg/mL.
CONCLUSIONS: The patient's serum contains heterophilic antibodies, which interfere with the TSH and ACTH tested by this method.