%0 Journal Article %T Evaluation of polypropylene microporous membranes as extraction devices for determination of carcinogenic aromatic amines in smoker urine by GC-MS/MS. %A Cestaro BI %A Nagata N %A da Silva BJG %J J Chromatogr A %V 1729 %N 0 %D 2024 Aug 16 %M 38838449 %F 4.601 %R 10.1016/j.chroma.2024.465030 %X Exposure to tobacco smoke is highly correlated to the incidence of different types of cancer due to various carcinogenic compounds present in such smoke. Aromatic amines, such as 1-naphthylamine (1-NA) and 2-naphthylamine (2-NA), are produced in tobacco burning and are linked to bladder cancer. Miniaturized solid phase extraction techniques, such as microporous membrane solid phase extraction (MMSPE), have shown potential for the extraction of aromatic compounds. In this study, a bioanalytical method for the determination of 1-NA and 2-NA in human urine was developed using polypropylene microporous membranes as a sorptive phase for MMSPE. Urine samples were hydrolyzed with HCl for 1 h at 80 °C, after which pH was adjusted to 10. Ultrasound-assisted MMSPE procedure was optimized by factorial design as follows. To each sample, 750 µL of methanol was added, and ultrasound-assisted MMSPE was conducted for 1 h with four devices containing seven 2 mm polypropylene membrane segments. After extraction, the segments were transferred to 400 µL of hexane, and desorption was conducted for 30 min. Extracts were submitted to a simple and fast microwave-assisted derivatization procedure, by the addition of 10 µL of PFPA and heating at 480 W for 3 min, followed by clean-up with phosphate buffer pH 8.0 and GC-MS/MS analysis. Adequate linearity was obtained for both analytes in a range from 25 to 500 µg L-1, while the multiple reaction monitoring approach provided satisfactory selectivity and specificity. Intra-day (n = 6) and inter-day (n = 5) precision and accuracy were satisfactory, below 15 % and between 85 and 115 %, respectively. Recovery rates found were 91.9 and 58.4 % for 1-NA and 2-NA, respectively, with adequate precision. 1-NA was found in first-hand smokers' urine samples in a concentration range from 20.98 to 89.09 µg in 24 h, while it could be detected in second-hand smoker's urine samples, and 2-NA detected in all first and second-hand smokers' urine samples. The proposed method expands the applicability of low cost MMSPE devices to aromatic amines and biological fluids.