%0 Journal Article %T Laparoscopic left hemihepatectomy using augmented reality navigation plus ICG fluorescence imaging for hepatolithiasis: a retrospective single-arm cohort study (with video). %A Deng H %A Zeng X %A Hu H %A Zeng N %A Huang D %A Wu C %A Fang C %A Xiang N %J Surg Endosc %V 38 %N 7 %D 2024 Jul 28 %M 38806956 %F 3.453 %R 10.1007/s00464-024-10922-8 %X BACKGROUND: Laparoscopic left hemihepatectomy (LLH) has been shown to be an effective and safe method for treating hepatolithiasis primarily affecting the left hemiliver. However, this procedure still presents challenges. Due to pathological changes in intrahepatic duct stones, safely dissecting the hilar vessels and determining precise resection boundaries remains difficult, even with fluorescent imaging. Our team proposed a new method of augmented reality navigation (ARN) combined with Indocyanine green (ICG) fluorescence imaging for LLH in hepatolithiasis cases. This study aimed to investigate the feasibility of this combined approach in the procedure.
METHODS: Between May 2021 and September 2023, 16 patients with hepatolithiasis who underwent LLH were included. All patients underwent preoperative 3D evaluation and were then guided using ARN and ICG fluorescence imaging during the procedure. Perioperative and short-term postoperative outcomes were assessed to evaluate the safety and efficacy of the method.
RESULTS: All 16 patients successfully underwent LLH. The mean operation time was 380.31 ± 92.17 min, with a mean estimated blood loss of 116.25 ± 64.49 ml. ARN successfully aided in guiding hilar vessel dissection in all patients. ICG fluorescence imaging successfully identified liver resection boundaries in 11 patients (68.8%). In the remaining 5 patients (31.3%) where fluorescence imaging failed, virtual liver segment projection (VLSP) successfully identified their resection boundaries. No major complications occurred in any patients. Immediate stone residual rate, stone recurrence rate, and stone extraction rate through the T-tube sinus tract were 12.5%, 6.3%, and 6.3%, respectively.
CONCLUSIONS: The combination of ARN and ICG fluorescence imaging enhances the safety and precision of LLH for hepatolithiasis. Moreover, ARN may serve as a safe and effective tool for identifying precise resection boundaries in cases where ICG fluorescence imaging fails.