%0 Journal Article %T Study on quality control methods and pharmacodynamic material basis of different specifications of Corydalis Rhizoma produced in Zhejiang Province. %A Li Y %A Zhao M %A Tang R %A Fang K %A Ye Y %A Zhu B %A Chen L %A Chen Y %A Ge W %A Du W %J J Ethnopharmacol %V 332 %N 0 %D 2024 Oct 5 %M 38789094 %F 5.195 %R 10.1016/j.jep.2024.118375 %X BACKGROUND: The quality control methods of different specifications of Corydalis Rhizoma in Zhejiang China (ZJ CR) are the same, so the quality of each specification couldnot be guaranteed. To clarify the quality control methods and pharmacodynamic material basis of ZJ CR with different specifications could provide reference for the quality control of ZJ CR.
OBJECTIVE: The purpose of this study was to establish a quality control method for ZJ CR with different specifications and to screen out the pharmacodynamic material basis of ZJ CR with different specifications.
METHODS: Firstly, according to the existing grading standards, the medicinal materials were divided into specifications, and the character indexes of ZJ CR with different specifications were established. The quality indexes were established by HPLC, network pharmacology and literature retrieval. The correlation between the trait indexes and quality indexes of ZJ CR with different specifications was analyzed, and the best quality control method was established. Further combined with the pharmacodynamic indexes of ZJ CR with different specifications, the pharmacodynamic material basis of ZJ CR with different specifications was screened out by spectrum-effect analysis. The correlation between trait indexes and pharmacodynamic indexes was analyzed to verify the rationality of grade standard.
RESULTS: The three specifications of ZJ CR were CR (Diameter ≥1.1 cm), CR (Diameter <1.1 cm), and CR (No size distinction). Diameter, width, thickness, grain weight, volume and 50 g grain number could be used as the trait indexes of ZJ CR. Protopine (CR1), palmatine hydrochloride (CR2), berberine hydrochloride (CR3), dehydrocorydaline (CR4), tetrahydropalmatine (CR5), tetrahydroberberine (CR6), corydaline (CR7), stylopine (CR8) and isoimperatorin (CR9) were identified. Total components, core components (CR5, CR6, CR7 and CR8), alcohol-soluble extracts (ASE) could be used as quality indexes. The best quality control methods of the three specifications respectively were: the larger the diameter and grain weight, the smaller the number of 50 g grains; The larger the diameter, the smaller the volume, thickness, width and number of 50 g particles; The larger the grain weight and volume, the smaller the number of 50 g grains. The main analgesic components of the three specifications respectively were: CR1, CR2 and core components; CR2, CR4; CR8, CR9. The larger the diameter and the less the number of 50 g grains, the better the analgesic effect of ZJ CR, and the grade standard was reasonable.
CONCLUSIONS: This study showed that the quality control methods and pharmacodynamic material basis of ZJ CR with different specifications were different, which may be caused by the differences in traits and the contribution of main active ingredients. This study constructed an evaluation model combining external traits, internal quality and overall efficacy, and provided theoretical support for the rationality of ZJ CR grade standard.