%0 Randomized Controlled Trial %T One-piece versus two-piece zirconia abutment supported single implant crown in the esthetic region: 3-Year results from a split-mouth randomized controlled clinical trial. %A Lv X %A Pu Y %A Zhang X %A Jiang X %A Zhang X %A Shi J %A Lai H %J Clin Oral Implants Res %V 34 %N 12 %D 2023 Dec 1 %M 37655630 %F 5.021 %R 10.1111/clr.14173 %X OBJECTIVE: To compare the clinical, radiographic, and immunological outcomes between one-piece versus two-piece zirconia abutments supported single implant crowns in the esthetic region.
METHODS: The study followed a split-mouth, double-blind, and randomized controlled clinical design for a duration of 3 years. Twenty-two eligible patients with 44 implants were randomly assigned to two groups: Group 1 (one-piece zirconia abutment with zirconia base, n = 22) and Group 2 (two-piece zirconia abutment with titanium base, n = 22). The primary outcome was the technical complication rate. Additionally, survival rates, cytokines concentrations in peri-implant crevicular fluid (PICF), peri-implant conditions, marginal bone loss, and pink/white esthetics score (PES/WES) were assessed as secondary outcomes.
RESULTS: Twelve of 22 patients attended the 1-year follow-up (due to the COVID pandemic), and 19 patients attended the 3-year examination. Two abutments in Group 1 were fractured after 10 and 12 months in function. Additionally, one screw loosening occurred in Group 1 at 1-year follow-up. The 3-year technical complication rate was significantly higher in Group 1 than that in Group 2 (15.79% vs. 0%, p < .001). The 3-year implant survival rate was 100% in both groups. The concentration of IFN-γ in PICF was significantly upregulated in Group 2 (p = .018). Furthermore, the IL-6 concentration was positively correlated with BOP% (p = .020).
CONCLUSIONS: Two-piece zirconia abutments exhibited superior technical performance compared to one-piece designs during a 3-year follow-up in the anterior region. However, further long-term research is necessary to verify the immunological stability of two-piece zirconia abutments.