%0 Journal Article %T Prophylactic Catheter Ablation of Ventricular Tachycardia in Ischemic Cardiomyopathy: a systematic review and meta-analysis of randomized controlled trials Electrophysiology Collaborative Consortium for Metaanalysis - ELECTRAM Investigators. %A Shah K %A Turagam M %A Patel B %A Natale A %A Lakkireddy D %A Garg J %J J Atr Fibrillation %V 13 %N 2 %D Aug 2020 %M 34950297 暂无%R 10.4022/jafib.2371 %X OBJECTIVE: Catheter ablation is an effective strategy for drug-refractory ventricular tachycardia (VT) in ischemic cardiomyopathy. We aimed to perform a systematic review and meta-analysis of outcomes of prophylactic catheter ablation (PCA) of Ventricular Tachycardia (VT) in ischemic cardiomyopathy patients.
METHODS: We performed a comprehensive literature search through February 10, 2020, for all eligible randomized controlled trials that compared "PCA" versus "No PCA" for VT. Primary efficacy outcomes included - appropriate ICD therapy (composite of anti-tachycardia pacing and ICD shock), appropriate ICD shocks, electrical storm, cardiac mortality, and all-cause mortality. The primary safety outcome was any adverse events.
RESULTS: Four randomized controlled trials (N = 505) met inclusion criteria. Prophylactic catheter ablation was associated significant reduction in appropriate ICD therapies (RR 0.70; 95% CI 0.55 - 0.89, p = 0.004), appropriate ICD shocks (RR 0.57 95% CI 0.40 - 0.80, p = 0.001) with a trend towards reduced risk of electrical storm (RR 0.64; CI 0.39 - 1.05; p = 0.075) compared to "No PCA". There was no significant difference in cardiac mortality (RR 0.66, 95% CI 0.31 - 1.43, p = 0.29) and all-cause mortality (RR 0.98, 95% CI 0.52 - 1.82, p = 0.94) with similar adverse events (RR 1.46, 95% CI 0.73 - 2.95, p = 0.29) between two groups.
CONCLUSIONS: Prophylactic catheter ablation in ischemic cardiomyopathy patients was associated with a lower risk of ICD therapies, including ICD shocks and VT storm with no difference in cardiac and all-cause mortality.