%0 Evaluation Study %T Clinical and patient-reported outcomes of zirconia-based implant fixed dental prostheses: Results of a prospective case series 5 years after implant placement. %A Spies BC %A Witkowski S %A Vach K %A Kohal RJ %J Clin Oral Implants Res %V 29 %N 1 %D Jan 2018 %M 28940708 %F 5.021 %R 10.1111/clr.13072 %X OBJECTIVE: To evaluate the clinical and patient-reported outcome of all-ceramic zirconia implant supported fixed dental prostheses (FDPs) 5 years after implant installation.
METHODS: Thirteen patients were treated with two terminally placed one-piece zirconia implants for a three-unit FDP each. The FDPs consisted of a CAD/CAM-fabricated zirconia framework over-pressed with a fluor-apatite veneering ceramic and were adhesively cemented. Survival and success were assessed by applying modified US Public Health Service (USPHS) criteria and preparation of Kaplan-Meier (KM) plots. Alpha and Bravo ratings were accepted for success (among others including small area veneer chippings and occlusal roughness), whereas Charlie ratings allowing for intra-oral correction (e.g., polishing) were accepted for survival. Furthermore, patient-reported outcome measures (PROMs) were analyzed with the help of visual analogue scales (VAS). Wilcoxon matched-pairs signed-rank test (USPHS criteria) and linear mixed models (PROMs) were used to evaluate time effects on response variables.
RESULTS: All patients were available 61.8 ± 1.1 months after implant installation (53.6 ± 3.1 months after final prosthesis insertion). FDP survival was 100%. Significant incidence of veneer chipping (p = .0096) and occlusal roughness (p = .0019) was observed. Charlie rated extent of both phenomena resulted in a KM success estimate of 38.5% (95% CI: 14.1%-62.8%; seven FDPs with obvious roughness, three of them with extended veneer chipping). Compared with the pre-treatment assessments (30%-81% of satisfaction), all surveys at prosthetic delivery showed significantly improved VAS scores (66%-93%; p ≤ .038), except for speech (p = .341). Concerning function, esthetics and self-esteem, no decrease in satisfaction could be observed until the end of follow-up (90%-96%; p ≥ .057), whereas perception of sense (92%) and speech (95%) increased over time (p ≤ .030). Occurrence of technical complications did not correlate with patient satisfaction.
CONCLUSIONS: Bi-layered FDPs made from zirconia/fluor-apatite highly satisfied patients but showed significant incidence of technical complications.