关键词: CT Cardiac Coronary Arteries Coronary Artery Calcium Score Low-Dose CT Scan Radiation Dose Reduction Radiation Safety Tin Filter kV-Independent

Mesh : Humans Middle Aged Female Male Radiation Dosage Prospective Studies Coronary Artery Disease / diagnostic imaging Coronary Vessels / diagnostic imaging Tomography, X-Ray Computed / methods Vascular Calcification / diagnostic imaging Tin / chemistry Aged Coronary Angiography / methods Reproducibility of Results

来  源:   DOI:10.1148/ryct.230246

Abstract:
Purpose To investigate the ability of kilovolt-independent (hereafter, kV-independent) and tin filter spectral shaping to accurately quantify the coronary artery calcium score (CACS) and radiation dose reductions compared with the standard 120-kV CT protocol. Materials and Methods This prospective, blinded reader study included 201 participants (mean age, 60 years ± 9.8 [SD]; 119 female, 82 male) who underwent standard 120-kV CT and additional kV-independent and tin filter research CT scans from October 2020 to July 2021. Scans were reconstructed using a Qr36f kernel for standard scans and an Sa36f kernel for research scans simulating artificial 120-kV images. CACS, risk categorization, and radiation doses were compared by analyzing data with analysis of variance, Kruskal-Wallis test, Mann-Whitney test, Bland-Altman analysis, Pearson correlations, and κ analysis for agreement. Results There was no evidence of differences in CACS across standard 120-kV, kV-independent, and tin filter scans, with median CACS values of 1 (IQR, 0-48), 0.6 (IQR, 0-58), and 0 (IQR, 0-51), respectively (P = .85). Compared with standard 120-kV scans, kV-independent and tin filter scans showed excellent correlation in CACS values (r = 0.993 and r = 0.999, respectively), with high agreement in CACS risk categorization (κ = 0.95 and κ = 0.93, respectively). Standard 120-kV scans had a mean radiation dose of 2.09 mSv ± 0.84, while kV-independent and tin filter scans reduced it to 1.21 mSv ± 0.85 and 0.26 mSv ± 0.11, cutting doses by 42% and 87%, respectively (P < .001). Conclusion The kV-independent and tin filter research CT acquisition techniques showed excellent agreement and high accuracy in CACS estimation compared with standard 120-kV scans, with large reductions in radiation dose. Keywords: CT, Cardiac, Coronary Arteries, Radiation Safety, Coronary Artery Calcium Score, Radiation Dose Reduction, Low-Dose CT Scan, Tin Filter, kV-Independent Supplemental material is available for this article. © RSNA, 2024.
摘要:
目的研究千伏独立能力(以下,kV无关)和锡滤波器光谱整形,以与标准120kVCT协议相比,准确量化冠状动脉钙积分(CACS)和辐射剂量减少。材料和方法本前瞻性,盲人读者研究包括201名参与者(平均年龄,60岁±9.8[SD];119名女性,82名男性),从2020年10月至2021年7月接受了标准120kVCT和额外的kV无关和锡过滤器研究CT扫描。使用用于标准扫描的Qr36f内核和用于模拟人工120kV图像的研究扫描的Sa36f内核重建扫描。CACS,风险分类,和辐射剂量通过方差分析分析进行比较,Kruskal-Wallis测试,曼-惠特尼测试,Bland-Altman分析,皮尔逊相关性,和κ分析的一致性。结果没有证据表明标准120kV之间的CACS存在差异,kV独立,和锡过滤器扫描,CACS中值为1(IQR,0-48),0.6(IQR,0-58),和0(IQR,0-51),分别(P=.85)。与标准的120kV扫描相比,kV无关扫描和锡滤波扫描在CACS值中显示出极好的相关性(分别为r=0.993和r=0.999),在CACS风险分类中具有很高的一致性(分别为κ=0.95和κ=0.93)。标准120kV扫描的平均辐射剂量为2.09mSv±0.84,而与kV无关的和锡过滤器扫描将其降低至1.21mSv±0.85和0.26mSv±0.11,削减剂量为42%和87%,分别(P<.001)。结论与标准120kV扫描相比,独立于kV和锡滤波器研究的CT采集技术在CACS估计中显示出极好的一致性和较高的准确性,辐射剂量大幅减少。关键词:CT,心脏,冠状动脉,辐射安全,冠状动脉钙积分,辐射剂量减少,低剂量CT扫描,锡过滤器,kV独立补充材料可用于本文。©RSNA,2024.
公众号