BACKGROUND: The frequency of primary joint replacement surgery continues to increase worldwide. While largely considered biologically inert entities, an increasing body of evidence continues to validate a not insignificant incidence of allergic reactions to such implants. Little previous work has explored genuinely immune-mediated reactivity in this context. In the absence of a contemporary published summary on the topic, this paper explored the current state of understanding of cobalt/chromium allergy and proposes a patient management algorithm whereby such immune reactions are clinically suggested.
METHODS: A structured, systematic literature review was performed by following PRISMA search principles to provide an updated review of this area.
RESULTS: Thirty-six topic-related articles were identified, the majority reflecting lower tiers of scientific evidence with a lack of homogeneous quantitative data to facilitate valid cohort comparisons. Largely, the available literature represented small case series\' or expert opinions.
CONCLUSIONS: Despite increasing clinical awareness and acknowledgement of true allergy to joint replacement components, this review highlighted that the evidence base underpinning the diagnosis and management of such patients is limited. Both patient-reported metal allergy or skin patch testing are grossly unreliable methods and show almost no correlation with true immune reactivity. Recent studies suggested a potential role for patient-specific in vitro cellular activation testing and/or targeted genetic testing when cobalt/chromium allergy is clinically suspected. However, while likely representing the contemporary \"best available\" approaches both can be costly undertakings, are not yet universally available, and still require broader validation in non-research settings before wider uptake can be championed.
摘要:
背景:在全球范围内,初次关节置换手术的频率持续增加。虽然在很大程度上被认为是生物惰性实体,越来越多的证据继续证实对这种植入物的过敏反应的发生率并不明显。在这种情况下,以前的工作很少探索真正的免疫介导的反应性。在没有关于该主题的当代出版摘要的情况下,本文探讨了钴/铬过敏的理解现状,并提出了一种患者管理算法,从而在临床上建议这种免疫反应。
方法:结构化,通过遵循PRISMA搜索原则进行系统文献综述,以提供该领域的最新综述.
结果:确定了36篇与主题相关的文章,大多数反映了较低级别的科学证据,但缺乏同质的定量数据来促进有效的队列比较。很大程度上,可用的文献代表小案例系列或专家意见。