关键词: ALT, alanine aminotransferase AST, aspartate aminotransferase AUCi, incremental area under the curve BMI, Body mass index BUN, blood urea nitrogen CI, confidence intervals Clinical trial Complete nutrition drink DM, Diabetes Mellitus ECLIA, electrochemiluminescence immunoassay FPG, fasting plasma glucose GI, Glycemic index Glycemic index HDL, high-density lipoprotein HDL-C, high-density lipoprotein cholesterol Healthy volunteers IPAQ, International physical activity questionnaire Insulin LDL, low-density lipoprotein MET, metabolic equivalent Personalised nutrition Postprandial glucose response Retrograded starch SD, standard deviation SE, standard error h, hour min, minute

Mesh : Blood Glucose Fasting Glucose Humans Insulin Starch

来  源:   DOI:10.1017/jns.2022.23   PDF(Pubmed)

Abstract:
Complete nutrition drinks with a low glycemic index (GI) provide nutritional support and prevent hyperglycaemia. The present study identified GI and factors predicting individual glucose response to a new complete nutrition drink. A randomised cross-over controlled trial was conducted in eighteen healthy volunteers (FPG < 100 mg/dl). Complete nutrition drinks containing retrograded starch, glucose solution and white bread were assigned in a random sequence with 14-day wash-out intervals. Plasma glucose and insulin levels were measured from baseline to 180 min after consuming each food. Results show the adjusted GIs of the drink was 48.2 ± 10.4 and 46.7 ± 12.7 with glucose and white bread as the reference, respectively. While the drink has low GI (<55), the individual glucose responses varied (GI: 7-149). Comparing characters in individual GI < 55 (n = 12) and GI ≥ 55 (n = 6) groups revealed significantly higher baseline insulin in the low GI group (14.86 ± 16.51 μIU/ml v. 4.9 ± 3.4 μIU/ml, P < 0·05). The correlation matrix confirms only two predictive factors for having individual GI <55 were baseline insulin (r = 0·5, P = 0·03) and HOMA-IR (r = 0·55, P = 0·02). ROC curve reveals fasting insulin above 1.6 μIU/ml and HOMA-IR above 1.05 as the cut-off values. The findings suggest that the complete nutrition drink has a low GI, but there was wide variability in individual responses partly explained by fasting insulin levels and HOMA-IR. Screening for fasting insulin and HOMA-IR may be encouraged to maximise the functional benefit of the drink.
摘要:
具有低血糖指数(GI)的完全营养饮料提供营养支持并预防高血糖。本研究确定了GI和预测个体对新的完全营养饮料的葡萄糖反应的因素。在18名健康志愿者(FPG<100mg/dl)中进行随机交叉对照试验。含有逆行淀粉的全营养饮料,葡萄糖溶液和白面包以随机顺序分配,间隔14天。从基线到食用每种食物后180分钟测量血浆葡萄糖和胰岛素水平。结果表明,以葡萄糖和白面包为参考,调整后的饮料GI分别为48.2±10.4和46.7±12.7,分别。虽然饮料具有低GI(<55),个体葡萄糖反应不同(GI:7-149)。比较个别GI<55(n=12)和GI≥55(n=6)组的特征显示,低GI组的基线胰岛素明显更高(14.86±16.51μIU/ml与4.9±3.4μIU/ml,P<0·05)。相关矩阵仅证实个体GI<55的两个预测因素是基线胰岛素(r=0·5,P=0·03)和HOMA-IR(r=0·55,P=0·02)。ROC曲线显示空腹胰岛素高于1.6μIU/ml,HOMA-IR高于1.05作为临界值。研究结果表明,完全营养饮料具有低GI,但个体反应存在很大差异,部分原因是空腹胰岛素水平和HOMA-IR.可以鼓励筛选空腹胰岛素和HOMA-IR以最大化饮料的功能益处。
公众号