关键词: Bladder management Clean intermittent catheterization Foreign body Neurogenic bladder Spinal cord injury

Mesh : Adult Female Foreign Bodies / etiology Humans Intermittent Urethral Catheterization / adverse effects Spinal Cord Injuries / complications Urinary Bladder, Neurogenic / etiology therapy

来  源:   DOI:10.1080/10790268.2018.1557862   PDF(Sci-hub)   PDF(Pubmed)

Abstract:
Context: Bladder dysfunction is common in patients with spinal cord injuries. Clean intermittent catheterization is a preferred method of neurogenic bladder management among spinal cord injured patients. Some complications may occur due to the use of clean intermittent catheterization.Findings: In this report, we presented a case with an unexpected foreign body detected in the bladder of a patient who used to perform clean intermittent catheterization for her neurogenic bladder management, to our knowledge, which has not been reported in the literature so far.Conclusion/Clinical Relevance: In this case report, we want to emphasis the importance of different kind of foreign bodies remaining in the bladder during clean intermittent catheterization.